| Kapasiti dinilai (KVA) | Gabungan voltan | Sertai label kumpulan | Kehilangan tanpa beban (W) | Kehilangan beban (W) | Impedans litar pintas (%) | Arus tanpa beban (%) | ||
| Ketegangan tinggi (KV) | Tapoff % | Tekanan rendah (KV) | ||||||
| S13-50/35 | 38.5 35 | ±5 ±2x2.5 | 0.4 | Dyn11 Yyn0 | 128 | 1200/1140 | 6.5 | 1.30 |
| S13-100/35 | 184 | 2010/1910 | 1.10 | |||||
| S13-125/35 | 216 | 2370/2260 | 1.10 | |||||
| S13-160/35 | 224 | 2820/2680 | 1.00 | |||||
| S13-200/35 | 272 | 3320/3160 | 1.00 | |||||
| S13-250/35 | 320 | 3950/3760 | 0.95 | |||||
| S13-315/35 | 384 | 4750/4530 | 0.95 | |||||
| S13-400/35 | 464 | 5740/5470 | 0.85 | |||||
| S13-500/35 | 544 | 6910/6580 | 0.85 | |||||
| S13-630/35 | 664 | 7860 | 0.65 | |||||
| S13-800/35 | 784 | 9400 | 0.65 | |||||
| S13-1000/35 | 920 | 11500 | 0.65 | |||||
| S13-1250/35 | 1120 | 13900 | 0.60 | |||||
| S13-1600/35 | 1350 | 16600 | 0.60 | |||||
| S13-2000/35 | 1590 | 19700 | 0.55 | |||||
| S13-2500/35 | 1890 | 23200 | 0.55 | |||||
| Kapasiti dinilai (KVA) | Sertai label kumpulan | Gabungan voltan | Arus tanpa beban % | Kehilangan tanpa beban W | Kehilangan beban (120℃)W | Voltan impedans % | ||
| Ketegangan tinggi (KV) | Julat pili tekanan tinggi % | Tekanan rendah (KV) | ||||||
| SCB10-315/35 | Yyn0 atau Dyn11 | 35 atau 38.5 | ±5atau ±2×2.5 | 0.4 3.15 6 6.3 10 10.5 11 | 2 | 1160 | 4170 | 6 7 8 9 |
| SCB10-400/35 | 2 | 1360 | 5360 | |||||
| SCBI10-500/35 | 2 | 1600 | 6590 | |||||
| SCB10-630/35 | 1.8 | 1840 | 7680 | |||||
| SCB10-800/35 | 1.9 | 2220 | 9350 | |||||
| SC810-1000/35 | 1.9 | 2640 | 10880 | |||||
| SCB10-1250/35 | 1.7 | 3090 | 12840 | |||||
| SCB10-1600/35 | 1.7 | 3650 | 15390 | |||||
| SCB10-2000/35 | 1.5 | 4200 | 18110 | |||||
| SCB10-2500/35 | 7.5 | 4800 | 21680 | |||||
| SCB10-3150/35 | 1.3 | 5000 | 24400 | |||||
| SC810-4000/35 | 1.3 | 6950 | 29330 | |||||
| SCB10-5000/35 | 1.1 | 8320 | 34770 | |||||
| SCB10-6300/35 | 1.1 | 9840 | 40630 | |||||
| SCB10-8000/35 | Yd11 or Ynd11 | 1 | 11200 | 45050 | ||||
| SCB10-10000/35 | 1 | 12800 | 51200 | 7 | ||||
| SC810-12500/35 | 0.9 | 16150 | 55300 | |||||
| SCB10-16000/35 | 0.8 | 19560 | 59800 | |||||
1. Proses Reka Bentuk Pencawang: Pendekatan Berperingkat Pencawang 110 kV mengambil masa 16 bulan dari konse...
BACA LAGITransformer kuasa 40MVA tersdanung pada perlindungan pembezaan selepas kerosakan penyuap rapat. Ujian minyak bersi...
BACA LAGIApakah itu Pengubah Keadaan Pepejal (SST)? Pada tahun 2022, juruterbang utiliti Eropah menggantikan pengubah...
BACA LAGIKrisis Kekurangan Transformer: Mengapa Loji Baharu Adalah Kritikal Lebih 80% daripada transformer kuasa besa...
BACA LAGI